FAQ

Answers to your Frequently Asked Questions

Get answers to commonly asked questions about radiation monitoring services, and Radiation Detection Company’s dosimeter badge services.

FAQ

Dosimeter Badges

Expert answers to common questions about dosimeter badges from Radiation Detection Company (RDC).

What does a radiation dosimetry badge measure?

A radiation dosimetry badge measures a person’s occupational exposure to ionizing radiation over time. Also called a radiation badge or a personnel dosimeter, it provides a documented record of radiation dose that helps organizations monitor exposure, identify unusual results, and support radiation safety and regulatory compliance.

Dosimetry badges measure exposure; they do not protect the wearer from radiation. Different dosimeter types are available for whole body, extremity, fetal, and area monitoring.

Workers who may be exposed to ionizing radiation as part of their job may need to wear a dosimetry badge to monitor and document their occupational radiation exposure.

This can include:

  • Healthcare professionals working with X-ray, fluoroscopy, nuclear medicine, or radiation therapy
  • Dental and veterinary professionals
  • Nuclear energy and Department of Energy workers
  • Researchers
  • Industrial radiographers
  • … and others who work with radiation-producing equipment or radioactive materials

Whether personnel dosimetry is required depends on the worker’s potential exposure, the radiation sources involved, and applicable federal or state regulations. Your Radiation Safety Officer (RSO) should evaluate workplace exposure and regulatory requirements to determine which employees need radiation monitoring.

For more information about regulatory monitoring thresholds, see “When is personnel radiation monitoring required?” in the Compliance section.

Yes. RDC supports multiple badge types per wearer. If a staff member requires both a whole body dosimeter badge and a ring badge for extremity monitoring (common for roles that involve frequent hand exposure near radiation sources), both can be added and managed under the same wearer profile in MyRadCare™.

No. Dosimetry badges are assigned to individual workers and should not be shared.

Sharing a dosimeter prevents the measured dose from being accurately attributed to a specific worker and can compromise occupational dose records. Each monitored employee should wear only the dosimeter assigned to them for the designated wear period.

If you need to add a new wearer to your dosimetry program, you can request an additional badge through MyRadCare™ or contact RDC for assistance.

A control badge is a dosimeter used to account for background and transit radiation exposure that personnel dosimeters may receive when they are not being worn, including during storage and shipment.

The control badge is not worn by an employee. It should be stored in a low-radiation area at your facility, away from occupational radiation sources and alongside unworn personnel badges when possible. An office, reception area, or other appropriate low-background location may be suitable.

When dosimeters are processed, the control badge reading helps RDC distinguish non-occupational exposure from the radiation dose received by monitored workers, supporting more accurate occupational dose reporting.

A passive dosimeter is a radiation monitoring device that measures accumulated ionizing radiation exposure over a specific wear period without requiring a battery or power source.

Common passive dosimeters include thermoluminescent dosimeters (TLDs) and optically stimulated luminescence (OSL) dosimeters. After the wear period ends, the dosimeter is returned for processing, and the measured exposure is documented in a dose report.

Passive dosimeters are commonly used for routine occupational radiation monitoring because they provide a reliable record of cumulative radiation exposure over time.

For more information, see our resource on Semi-Passive and Passive Dosimeters.

An active dosimeter is an electronic radiation monitoring device that provides real-time information about a worker’s radiation exposure. Active dosimeters can measure accumulated dose and dose rate as exposure occurs, allowing workers to see changes in their radiation environment in the moment.

Depending on the device, active dosimeters may also provide visual or audible alerts when radiation levels or predetermined dose thresholds are reached. This immediate feedback can be useful in environments with fluctuating radiation levels and for dose optimization and ALARA programs.

Active dosimeters are generally used to complement rather than replace passive or semi-passive personnel dosimetry used for long-term occupational dose tracking and dose-of-record requirements.

RDC’s Radiant real-time dosimetry system provides real-time visibility into radiation exposure, helping clinical teams identify when and where exposure occurs and make adjustments while a procedure is underway.

Thermoluminescent dosimeters (TLDs) and optically stimulated luminescence (OSL) dosimeters are both passive dosimeters used to measure cumulative occupational exposure to ionizing radiation over a designated wear period. The primary difference is how the stored radiation exposure is measured during processing.

TLD dosimeters use radiation-sensitive materials that release stored energy as light when heated. The amount of light emitted is used to determine the radiation dose received during the wear period.

OSL dosimeters use radiation-sensitive materials that release stored energy as light when stimulated with a specific wavelength of light. That emitted light is then measured to determine radiation dose.

Both technologies can be used for routine personnel monitoring. The appropriate dosimeter depends on factors such as the radiation types and energies present, monitoring application, work environment, and program requirements.

RDC offers both TLD dosimeters and OSL dosimeters for occupational radiation monitoring. For more information, see our comparison – TLD vs. OSL Dosimeter: Comparison Using NVLAP Lab Data on Fade, LLD, and Reread Accuracy.

A neutron dosimeter is a personnel dosimeter designed to measure occupational exposure to neutron radiation.

Neutron monitoring may be needed when workers are exposed to neutron-producing sources or equipment, such as certain nuclear energy, research, accelerator, and industrial environments.

Because neutron radiation has different characteristics than X-ray, gamma, or beta radiation, a dosimeter must be designed and qualified for the radiation types present in the workplace. The appropriate monitoring method should be determined by your Radiation Safety Officer (RSO) based on the radiation source, potential exposure, and applicable regulatory requirements.

RDC offers a TLD + Neutron dosimeter for organizations that require neutron monitoring as part of their radiation safety program.

Yes. In addition to personal dosimeters for individual wearers, you can request an area monitoring dosimeter to track radiation levels in a specific room or location. Area monitors are managed directly through MyRadCare™ alongside your wearers.

FAQ

Dosimetry Service

Expert answers to common questions about dosimetry service with RDC.

How is RDC’s dosimetry service different from other providers?

Radiation Detection Company has provided personnel dosimetry services since 1949, combining accredited dosimetry, responsive customer support, transparent pricing, and online program management tools.

RDC customers benefit from:

  • NVLAP-accredited dosimetry: RDC is accredited through the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 100512-0.
  • Dedicated customer support: RDC’s customer care and technical teams are available to help with account management, dosimetry questions, and radiation monitoring needs.
  • MyRadCare™ included with service: Manage wearers, access dose reports, track badges and shipments, manage invoices, and more through RDC’s online dosimetry management platform.
  • Transparent pricing: Service includes account setup and management, standard badge delivery, and routine account changes at no additional charge.
  • Multiple dosimetry options: RDC offers passive, digital, extremity, fetal, neutron, and other monitoring solutions to support different occupational radiation environments.
  • Switching and onboarding support: SwitchAssist™ helps organizations transition their dosimetry program to RDC while coordinating wearer information, monitoring schedules, and program setup.

For a more detailed comparison of dosimetry providers, see our dosimetry provider comparison guide.

RDC offers both standard and expedited delivery options for dosimetry badges. For straightforward orders requiring a single badge type, badges can be delivered in as little as 2 business days with rush processing or approximately 7-10 business days with standard shipping.

Timing for larger or more complex dosimetry programs may depend on the number of wearers, badge types, locations, reporting requirements, and onboarding needs. RDC can also coordinate a future start date for organizations switching from another dosimetry provider. For more information on what to expect when switching dosimetry providers, please see our resource: How to Switch Dosimetry Providers Without Compliance Gaps or Disruption.

No. RDC’s dosimetry badge service is subscription-based, so you do not need to place a new order for each wear period. Dosimeters for the next wear period are automatically issued based on your account’s established wear frequency (monthly, bi-monthly, quarterly, semi-annually, or annually).

You only need to place an additional order when your monitoring needs change – for example, when adding a new wearer or requesting a replacement badge.

This helps keep your dosimetry program on schedule without requiring your team to manually reorder badges for every monitoring period.

If a new employee needs radiation monitoring before your next scheduled badge shipment, RDC can provide a new dosimeter outside your regular order cycle. Rush processing and expedited delivery options are available for urgent needs, with badges available for delivery in as little as 2 business days.

Organizations that frequently add new employees may also choose to keep appropriately configured spare dosimeters available for upcoming hires. Your RSO should ensure that each dosimeter is properly assigned before it is worn so the employee’s occupational dose is accurately recorded.

RDC customers receive access to MyRadCare™, our online customer platform for managing their dosimetry program. MyRadCare™ is included in the cost of dosimetry service.

Radiation Safety Officers and authorized administrators can use MyRadCare™ to manage badge wearers, access dose reports, order or replace badges, track shipments, manage invoices, and receive important account and reporting notifications.

Organizations with larger, multi-location, or more complex radiation safety programs can also use MyRadCare+ for enhanced program oversight, analytics, badge tracking, and additional radiation safety management capabilities.

After the wear period ends, return your used dosimetry badges to RDC for processing as soon as possible.

Customers can arrange and pay for their own return shipping using the carrier of their choice, or use EasyReturns, RDC’s prepaid return shipping option. EasyReturns provides a convenient way to return badges without arranging postage for each shipment.

For the most accurate and timely dose reporting, keep badges together and return them promptly after each wear period.

Yes. RDC offers EasyReturns, an optional prepaid return shipping service that simplifies sending worn dosimeters back to RDC for processing.

With EasyReturns, return shipping is arranged as part of your dosimetry service, reducing the administrative work of preparing return shipments for each wear period. EasyReturns is available for an additional fee.

If a dosimetry badge is lost or damaged during a wear period, RDC can provide a replacement so monitoring can continue. Replacement badges can be ordered through MyRadCare™ or by contacting RDC.

Because a lost or damaged dosimeter may affect the availability of a measured dose for that wear period, your Radiation Safety Officer should follow applicable procedures for documenting or estimating the worker’s occupational dose when necessary.

Additional fees may apply for lost or unreturned dosimeters.

RDC offers several wear periods for passive dosimetry programs, including:

  • Monthly
  • Bi-monthly
  • Quarterly
  • Semi-annually
  • Annually

The appropriate wear period depends on your monitoring needs, anticipated radiation exposure, and applicable regulatory requirements. Your Radiation Safety Officer (RSO) can help determine the appropriate monitoring frequency for your program.

Digital dosimetry solutions such as NetDose™ do not require routine badge exchanges.

FAQ

Compliance & Radiation Safety Regulations

Common questions about how Radiation Detection Company’s dosimeter badge services support radiation compliance and radiation safety monitoring.

How can I stay compliant with radiation safety regulations?

Radiation safety requirements vary based on your facility, radiation sources, employee exposure, and applicable federal or state regulations. A compliant radiation safety program may include personnel monitoring, occupational dose limits, recordkeeping, ALARA practices, employee training, and appropriate radiation protection controls.

Your Radiation Safety Officer (RSO) or other qualified radiation safety professional should evaluate the requirements that apply to your organization and ensure your monitoring program meets applicable regulations.

For state-specific requirements, download RDC’s 50 State Guide to Radiation Safety. You can also visit our Radiation Industry Links for regulatory agencies and additional radiation safety resources.

Under US Nuclear Regulatory Commission (NRC) regulations, the annual occupational dose limit for an adult radiation worker includes a total effective dose equivalent (TEDE) of 5 rem (5,000 mrem or 50 mSv).

Additional limits apply to specific tissues and organs:

  • Whole body (TEDE): 5,000 mrem per year
  • Lens of the eye: 15,000 mrem per year
  • Skin or extremities: 50,000 mrem per year
  • Declared embryo/fetus: 500 mrem during pregnancy

These are regulatory dose limits, not recommended exposure targets. Radiation safety programs should follow the ALARA (As Low As Reasonably Achievable) principle to minimize occupational radiation exposure.

Requirements may vary by regulatory jurisdiction. See 10 CFR § 20.1201 for adult occupational dose limits and 10 CFR § 20.1208 for dose limits during pregnancy.

Under NRC regulations, personnel radiation monitoring is required for adult workers who are likely to receive, in one year, more than 10% of the applicable occupational dose limits from external radiation sources.

Monitoring requirements also apply in certain circumstances to minors, declared pregnant workers, and individuals entering high or very high radiation areas.

Requirements can vary by regulatory jurisdiction and type of radiation work. Your Radiation Safety Officer (RSO) should evaluate anticipated exposure and applicable federal or state regulations to determine which employees require personnel dosimetry.

For NRC requirements, see 10 CFR § 20.1502.

Personnel dosimetry provides radiation safety teams with documented exposure data that can be used to monitor individual and group dose, identify trends, investigate unusual results, and evaluate opportunities to reduce occupational exposure.

Dose reports and exposure data can help Radiation Safety Officers (RSOs) assess how work practices, shielding, procedure changes, and other radiation protection measures affect employee exposure over time.

Dosimetry does not reduce radiation exposure by itself. It provides the information organizations need to make informed radiation safety decisions and keep occupational doses As Low As Reasonably Achievable (ALARA).

Occupational radiation dose records help organizations document employee exposure over time and demonstrate that their radiation safety program is being appropriately managed.

When personnel monitoring is required under NRC regulations, licensees must maintain records of individual monitoring results. These records can also help Radiation Safety Officers (RSOs) identify exposure trends, investigate unusual results, support ALARA practices, and maintain an individual’s occupational dose history.

Recordkeeping requirements vary by regulatory jurisdiction and the type of radiation source being used. Organizations should follow applicable federal or state requirements for maintaining occupational radiation exposure records.

For more guidance on state regulations, please see our Free 50 State Guide to Radiation Safety Requirements.

A dose report showing little or no occupational radiation exposure can be a positive indication that existing radiation safety practices are effective, but it does not necessarily mean personnel monitoring should be discontinued.

Radiation exposure can change as equipment, procedures, workloads, job responsibilities, or workplace conditions change. Continued dosimetry can provide an ongoing record of occupational exposure and help Radiation Safety Officers (RSOs) identify changes or unexpected exposure over time.

Whether personnel monitoring is required should be based on the worker’s potential exposure and applicable federal or state regulations. If monitoring is not required, an organization may still choose to continue dosimetry as part of its radiation safety and ALARA program.

Under NRC regulations, personnel monitoring is required for occupationally exposed minors who are likely to receive, in one year, more than:

  • 100 mrem (1 mSv) deep dose equivalent
  • 150 mrem (1.5 mSv) lens dose equivalent
  • 500 mrem (5 mSv) shallow dose equivalent to the skin or extremities

Occupational dose limits for minors are also restricted to 10% of the corresponding annual dose limits for adult radiation workers.

Requirements may vary by regulatory jurisdiction. Your Radiation Safety Officer (RSO) should evaluate the minor’s anticipated exposure and applicable federal or state regulations to determine whether personnel dosimetry is required.

See 10 CFR § 20.1502 for monitoring requirements and 10 CFR § 20.1207 for occupational dose limits for minors.

A radiation leak test, sometimes called a sealed source leak test or wipe test, is used to determine whether radioactive material is leaking from a sealed radioactive source.

During a leak test, a sample is collected from the sealed source or an accessible surface where radioactive contamination would be likely to accumulate if the source were leaking. The sample is then analyzed for removable radioactive contamination. NRC guidance specifies that analysis of required leak-test samples must be performed using appropriate instrumentation and, when provided as a commercial service, by an organization authorized by the NRC or an Agreement State.

Leak-testing requirements and testing intervals depend on the type of sealed source, its activity and use, applicable regulations, license conditions, and regulatory jurisdiction. Organizations should follow the requirements established by the NRC or their applicable Agreement State radiation control program.

RDC provides radiation leak test kits and analysis services for organizations that need to test sealed radioactive sources. Contact RDC for current leak testing options and pricing.

Possibly. Digital X-ray equipment still produces ionizing radiation, so using digital rather than film-based imaging does not eliminate the potential need for personnel dosimetry.

Whether employees need dosimetry badges depends on factors such as their anticipated occupational exposure, the types and frequency of procedures performed, shielding and work practices, and applicable federal or state regulations.

Your Radiation Safety Officer (RSO) or other qualified radiation safety professional should evaluate workplace exposure and regulatory requirements to determine which employees, if any, require personnel monitoring.

For state-specific radiation safety requirements, see RDC’s 50 State Guide to Radiation Safety.

FAQ

Dosimetry Accreditation

Common questions about Radiation Detection Company’s certifications, compliance, accreditations, and expertise as it pertains to dosimetry lab and badge services.

Is Radiation Detection Company NVLAP-accredited?

RDC is accredited to provide dosimetry services with the National Voluntary Laboratory Accreditation Program which is part of the National Institute of Standards and Technology (NIST). NVLAP Lab Code 100512-0.

You can learn more about Radiation Detection Company’s certifications and licenses here. 

NVLAP Accreditation
RDC is accredited to provide dosimetry services with the National Voluntary Laboratory Accreditation Program (NVLAP) which is part of the National Institute of Standards and Technology (NIST). NVLAP Lab Code 100512-0.

Licensing
RDC is licensed by the State of Texas, Department of State Health Services for dosimeter testing and collection/analysis of leak test (swipe) samples.

The mission of the Texas Department of State Health Services’ Radiation Control Program is to protect and promote the physical and environmental health of the people of Texas. They strive to prevent unnecessary radiation exposure to the public through effective licensing, registration, inspection, enforcement, and emergency response. 

You can learn more about Radiation Detection Company’s certifications and licenses here.

Yes. RDC’s NVLAP-accredited personnel dosimetry meets the applicable ANSI/HPS N13.11 performance requirements within RDC’s accredited scope.

RDC’s dosimetry laboratory is accredited through the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 100512-0. NVLAP evaluates personnel dosimetry laboratories through proficiency testing and technical requirements based on applicable ANSI/HPS standards.

For more information about RDC’s accreditation and current scope, visit the Accreditation section of our Learning Center.

FAQ

Fetal Monitoring

Expert answers to your most common questions about fetal monitoring badges and occupational radiation safety for pregnant employees.

What are the radiation monitoring requirements for pregnant employees?

Under NRC regulations, a radiation worker may voluntarily declare their pregnancy in writing to their employer. Once the pregnancy is declared, the occupational dose limit to the embryo/fetus is 500 mrem (5 mSv) over the entire pregnancy.

The NRC also requires employers to make efforts to avoid substantial variation above a uniform monthly exposure rate to the embryo/fetus.

Whether a fetal dosimeter is required depends on anticipated exposure and the regulations that apply to your facility. Your Radiation Safety Officer (RSO) should evaluate monitoring requirements and appropriate dosimeter placement for the declared pregnant worker.

For more information, see 10 CFR § 20.1208.

Yes. RDC provides fetal dosimetry badges for pregnant radiation workers who need or choose to monitor occupational radiation exposure during pregnancy.

Fetal monitoring can be added to an existing RDC dosimetry program, or RDC can help establish a dedicated monitoring group for organizations that do not already have one. Fetal dosimeters provide a separate dose record to help Radiation Safety Officers (RSOs) monitor occupational radiation exposure to the embryo/fetus throughout the pregnancy.

A fetal dosimeter badge should be worn directly over the fetal area in order to receive the most accurate reading and dose report. For more information, please see our resource – Radiation Dosimeter Badge: Complete Guide to Proper Wear, Maintenance, & Radiation Safety.

No, only one badge is required for the fetal area. Declared pregnant workers typically wear one fetal monitoring badge and one whole body dosimetry badge. Pregnant employees should confirm requirements with their Radiation Safety Officer.

Yes. Exposure to X-rays does not make a person or their breast milk radioactive, so breastfeeding can generally continue normally after an X-ray procedure or occupational exposure to X-ray radiation.

X-rays are a form of external radiation and are only produced while the X-ray equipment is energized. Once the exposure ends, no X-ray radiation remains in the body or breast milk.

This is different from some nuclear medicine procedures that use radioactive materials, which may require breastfeeding to be temporarily interrupted. Anyone who is breastfeeding and receives a radioactive drug or treatment should follow the instructions provided by their healthcare provider or radiation safety team.

FAQ

Dose Reports

Common questions about dose reports from Radiation Detection Company.

What is a dose report?

A dose report is a record of the occupational radiation exposure measured by a dosimeter during a specific wear period. It helps Radiation Safety Officers (RSOs) and employers monitor employee exposure, identify dose trends, and maintain required occupational radiation dose records.

RDC dose reports include the dose recorded for each monitored individual, along with cumulative dose information for the current year and lifetime monitoring history. Depending on the dosimeter and monitoring program, reports may include deep dose equivalent (DDE), lens dose equivalent (LDE), and shallow dose equivalent (SDE).

RDC customers can access and download Dose Reports through MyRadCare™.

Returned dosimeter badges are read and reports are mailed and available online within 10 days of badge receipt.

If you are using RDC’s online account management program, an email will be sent to you when your reports are available for viewing, downloading, and printing.

If you are not using our online account management program, your dose reports will be mailed to you.

For RDC’s passive dosimeters, 10 mrem is the minimum reportable dose. The minimum reportable dose for NetDose™ digital dosimeter is 1 mrem (0.01 mSv) per month.

If you have questions about a dose result or how to interpret your dose report, RDC’s technical team can help.

RDC supports standard dose reporting as well as Webster calculations for workers who wear lead aprons in non-uniform radiation fields.

RDC uses two Webster calculation methods:

  • Webster 1: Uses one dosimeter worn at the collar outside the lead apron. The modified Webster calculation is EDE = 0.3 × collar Hp(10).
  • Webster 2: Uses two dosimeters – one worn at the collar outside the apron and one worn under the apron at the torso or waist. The original Webster calculation is EDE = (1.5 × under-apron Hp(10)) + (0.04 × collar Hp(10)).

The appropriate method depends on the number and placement of dosimeters and applicable regulatory requirements. Because terminology can vary between dosimetry providers, organizations should clearly document the dosimeter placement and calculation method used.

For more information about EDE reporting, see “What is an EDE (Webster) dose calculation?” below.

A Webster calculation is a method used to estimate whole body radiation dose for workers who wear protective lead aprons. Because a lead apron shields part of the body while areas such as the head and neck remain unshielded, a single dosimeter reading may not fully represent the worker’s effective dose.

Webster calculations use readings from one or two dosimeters, depending on the method, to account for this non-uniform exposure and provide a more representative estimate of effective dose equivalent.

Requirements and accepted calculation methods can vary by jurisdiction and by dosimetry provider. Radiation safety teams should verify which method is permitted by their applicable regulatory authority and clearly document dosimeter placement and the calculation method used.

For more information, please see Webster Calculations Explained: Cutting Through Confusion to Improve Dose Accuracy and Compliance.

Environmental reports are designated for RDC’s type 82E and type 83E environmental dosimeters. These reports are printed at the end of the regular reports and have the letter “E” at the end of the report number. There is currently no accreditation available for environmental dosimeters and our current NVLAP (Lab Code 100512-0) accreditation requires all non-accredited dosimeters to be reported on a separate page.

Radiation dose record retention requirements depend on the regulations that apply to your organization. Under US Nuclear Regulatory Commission (NRC) regulations, records of individual monitoring results required by 10 CFR 20.2106 must be maintained until the NRC terminates the license.

State requirements may differ, so organizations should follow the record retention requirements established by their applicable regulatory authority. Radiation Safety Officers (RSOs) should maintain occupational dose records in a way that preserves each monitored worker’s dose history and makes required records available for regulatory review.

As a best practice, RDC recommends retaining dose reports, whether paper or electronic, for as long as your organization is in business. Maintaining historical dose records can also provide important documentation if questions about a former employee’s occupational radiation exposure arise years later.

See how historical dose reports helped Villano Family Dental respond to a legal dispute involving alleged occupational radiation exposure.

Yes. Badge wearers can use RDC’s DoseCheck™ tool to view their personal radiation dose information online.

DoseCheck provides individual wearers with convenient access to their dose history, while authorized account administrators can access and manage formal dose reports through MyRadCare™.

Check your dose with DoseCheck™.

If a dose result is unusually high or exceeds an established notification level, it may require additional review or investigation by your Radiation Safety Officer (RSO).

RDC provides dose reporting and notification tools to help radiation safety teams identify elevated results and monitor exposure trends. Your organization can then evaluate the result, investigate potential causes, and determine whether corrective action or additional monitoring is appropriate.

If you have questions about an unexpected dose result, contact RDC’s technical support team for assistance interpreting the report.

Yes, it is possible for a control badge to have a dose reading. Control badges can be exposed to natural background radiation and radiation received during storage and transit; a control dosimeter will usually record a small dose (5-20 mrem per month).

The control badge is used to help account for this non-occupational exposure when personnel dosimeters are processed. Because background and transit conditions vary, there is not a single expected dose reading that applies to every control badge.

If a control badge shows an unusually high result, contact RDC for assistance reviewing the reading and determining whether additional investigation may be appropriate.

RDC radiation dose reports use millirem (mrem).

FAQ

MyRadCare™

Expert answers to common questions about our online customer portal. 

What is MyRadCare™ and how can I benefit from it?

MyRadCare™ is RDC’s online dosimetry management platform, included at no additional cost for active RDC customers. It gives Radiation Safety Officers (RSOs) and authorized administrators centralized access to the tools and information they need to manage their dosimetry program.

With MyRadCare™, authorized users can:

  • View and download dose reports
  • Create NRC Form 5 reports
  • Add, remove, and update badge wearers
  • Order badges for new wearers and replacements for lost or damaged dosimeters
  • Track badge shipments, issuance, and returns
  • View, pay, and download invoices
  • Receive notifications for reports, shipments, invoices, and unreturned badges
  • Manage users, permissions, locations, and notification recipients

MyRadCare™ helps reduce the administrative work of managing a dosimetry program while keeping important dose, badge, and account information accessible in one place.

Yes. RDC can add multiple service locations to a single account number, making it easier to manage wearers, reports, and invoices across all your sites. Each location can have its own shipping address, badge type, wear frequency, and contact information, while still being accessible from one MyRadCare™ login. Simply contact our team by phone, chat, or email with a few details, and we’ll take care of adding the new locations to your account.

MyRadCare™ is included at no additional cost for active RDC dosimetry customers.

Yes. MyRadCare™ supports multiple authorized users and access levels, allowing organizations to give the appropriate team members access to their dosimetry program.

Admins can manage users and permissions, while other authorized users can be assigned different levels of access, including access limited to specific locations or groups. This makes it easier for Radiation Safety Officers, department managers, billing contacts, and other stakeholders to share responsibility for managing a dosimetry program without giving every user the same level of access.

Yes. MyRadCare™ lets you configure three separate notification streams (primary account notifications, dose report alerts, and invoice notifications) and assign different email recipients to each.

For example, your RSO can receive dose alerts, your billing contact can receive invoice notifications, and your office manager can receive account and shipping updates.

Recipients can be easily added or removed within the Admin tab in MyRadCare™.

No. MyRadCare™ is designed for authorized account administrators and other users responsible for managing an organization’s dosimetry program.

Individual badge wearers can use DoseCheck™ to access their available personal dose information without needing access to the organization’s MyRadCare™ account. DoseCheck™ is included with RDC dosimetry service, giving monitored employees convenient access to their own radiation dose information while administrators manage the overall program through MyRadCare™.

DoseCheck™ is RDC’s online tool that allows individual badge wearers to access their personal radiation dose information.

Unlike MyRadCare™, which is designed for authorized account administrators to manage an organization’s dosimetry program and access dose reports, DoseCheck gives individual wearers a convenient way to review their own dose information.

Check your dose with DoseCheck™.

MyRadCare™ is RDC’s online dosimetry management platform and is included with standard dosimetry service. It gives authorized users access to the tools they need to manage wearers, access dose reports, track shipments, manage account information, and oversee their dosimetry program online.

MyRadCare+ adds enhanced program-management capabilities, including advanced analytics and AI-powered insights, electronic signatures, and expanded badge tracking tools.

MyRadCare is designed to simplify day-to-day dosimetry management, while MyRadCare+ provides additional tools for organizations that want greater visibility, automation, and insight across their radiation safety program.

MyRadCare Insights™ is an AI-powered analytics capability within MyRadCare+ that helps radiation safety teams identify trends and gain greater visibility into their dosimetry data. 

Rather than reviewing dose records individually, Radiation Safety Officers (RSOs) and program administrators can use MyRadCare Insights™ to more efficiently evaluate exposure data, identify patterns that may warrant attention, and support proactive radiation safety and ALARA program management.

MyRadCare Insights™ is available as part of MyRadCare+ and is designed for organizations that need deeper visibility into radiation exposure across their dosimetry program.

FAQ

Billing & Invoices

Answers to common questions about Radiation Detection Company’s billing and invoice options.

What payment methods does RDC accept?

RDC accepts credit card, debit card, and ACH payments. Customers can also set up and manage automatic payments through MyRadCare™.

Credit card payments are subject to a 2.75% processing fee. Debit card and ACH payments do not incur this fee.

RDC offers prepaid and invoiced billing options based on the size of your dosimetry program.

  • Prepaid accounts: Dosimetry programs with 20 or fewer badges per wear period are prepaid. Customers maintain a positive account balance that is applied to badge service and other applicable charges.
  • Invoice accounts: Dosimetry programs with 21 or more badges per wear period may qualify for postpaid invoicing with NET 30 payment terms.

Billing is based on actual service usage and applicable RDC pricing. Additional services, such as rush processing, expedited shipping, or unreturned dosimeter fees, may be billed separately.

Contact RDC for help determining the billing arrangement that best fits your dosimetry program.

RDC can accommodate billing and invoicing needs for organizations managing dosimetry programs across multiple locations, departments, or groups.

Depending on your account structure and program needs, billing can be organized to simplify invoice management across your organization. Options may include consolidated or location-specific invoicing.

RDC’s team can work with your organization during account setup to establish an account and billing structure that aligns with your dosimetry program and internal accounting requirements.

Invoices and account balances can also be accessed and managed online through MyRadCare™, with invoice notifications assigned to designated billing contacts.

Yes. Authorized users can access invoices through MyRadCare™, RDC’s online dosimetry management platform. MyRadCare™ allows customers to view, download, print, and pay invoices online and access billing information 24/7.

Organizations can also assign invoice notifications to designated billing contacts, helping ensure the appropriate team members receive billing information without requiring access to other account notifications.

No. RDC does not charge setup, account management, or routine account-change fees as part of our standard dosimetry service.

Your dosimetry service includes account setup and onboarding, ongoing account management, access to MyRadCare™, dose reporting, and routine changes such as adding or updating badge wearers.

Additional charges may apply for optional or exception services, such as rush processing, expedited shipping, EasyReturns, unreturned dosimeters, or MyRadCare+ services. RDC provides transparent pricing so organizations can understand what is included in their dosimetry program and where additional charges may apply.

FAQ

Pricing & Dosimetry Program Costs

Answers to common questions about dosimeter badge program costs and Radiation Detection Company’s pricing.

How much do radiation dosimetry badges cost?

The cost of radiation dosimetry badges depends on your monitoring needs, including the type of dosimeter, number of wearers, wear frequency, and any optional services you choose. RDC also offers volume discounts, so larger dosimetry programs may have a lower per-badge cost.

For example, pricing may vary depending on whether your program uses whole body, extremity, fetal, neutron, or digital dosimeters and whether badges are exchanged monthly, bi-monthly, or quarterly. Optional services such as expedited shipping or EasyReturns can also affect your total program cost.

Use RDC’s online dosimetry badge pricing calculator to estimate the cost of your program based on your specific monitoring needs. For larger, multi-location, or more complex programs, request a custom quote to ensure your pricing reflects applicable volume discounts and the specific needs of your dosimetry program.

RDC’s standard dosimetry service includes:

  • Dosimeters and standard badge delivery
  • Dosimeter processing and dose reporting
  • Access to MyRadCare™ for online program management
  • Account setup and routine account changes
  • Customer and technical support
  • Control badges, as applicable to your monitoring program

RDC does not charge additional setup, account management, or routine account-change fees.

With 99% customer satisfaction, RDC is committed to providing accurate dosimetry, responsive support, and straightforward service throughout your monitoring program.

Use RDC’s online pricing calculator to estimate your dosimetry program cost, or request a custom quote for larger, multi-location, or more complex programs.

For more information, see our guide on How Dosimetry Badge Pricing Works.

Return shipping for worn passive dosimeters is not included in standard RDC dosimetry pricing. Customers can arrange and pay for return shipping themselves or add EasyReturns, RDC’s optional prepaid return shipping service.

With EasyReturns, a prepaid return shipping label is included with your badge delivery, making it easier to return worn dosimeters to RDC for processing at the end of each wear period.

Outbound delivery of your dosimetry badges is included with standard RDC service. Additional charges may apply for expedited shipping or other optional delivery services.

EasyReturns is an optional add-on to RDC’s dosimetry service. Pricing depends on your dosimetry program and return shipping needs.

With EasyReturns, a prepaid return shipping label is included with your badge delivery, making it easy to return worn passive dosimeters to RDC for processing at the end of each wear period.

Use RDC’s online pricing calculator to view current EasyReturns pricing when setting up a new dosimetry program. For existing customers, multi-location organizations, or more complex programs, contact RDC for pricing and to add EasyReturns to your service.

Yes. RDC charges an unreturned dosimeter fee for TLD or OSL badges that are lost or not returned for processing.

If a badge is lost during the wear period, notify RDC and request a replacement so monitoring can continue. If the original badge is later found and returned within 60 days of the end of the most recent wear period, a partial credit will be applied to your account.

Unreturned dosimeter fees are separate from standard dosimetry service pricing.

RDC’s standard dosimetry pricing includes account setup and management, standard badge delivery, routine account changes, dosimeter processing, dose reporting, and access to MyRadCare™ without additional administrative fees.

Additional charges may apply for optional services or exceptions, including rush processing, expedited shipping, EasyReturns prepaid return shipping, MyRadCare+, and lost or unreturned dosimeters.

RDC provides transparent pricing so organizations can understand what is included in their dosimetry program and which optional or exception services may result in additional charges.

For an estimate based on your program size and monitoring needs, use RDC’s online pricing calculator or contact our team for a custom quote.

FAQ

Dosimetry Terminology

Definitions of radiation safety monitoring terms and dosimetry acronyms.

What is dosimetry?

Dosimetry is the measurement, calculation, and assessment of radiation dose. In occupational radiation safety, personnel dosimetry is used to measure and document the ionizing radiation exposure workers receive as part of their job.

Radiation dosimetry programs typically use devices such as whole body badges, ring dosimeters, digital dosimeters, or other personnel monitors to measure exposure over time.

The resulting dose records help Radiation Safety Officers monitor exposure, identify trends, support ALARA practices, and maintain required occupational dose records.

Ionizing radiation is radiation with enough energy to remove electrons from atoms, creating electrically charged particles called ions. Common types of ionizing radiation include X-rays, gamma rays, alpha particles, beta particles, and neutron radiation.

Ionizing radiation occurs naturally in the environment and is also produced by equipment and radioactive materials used in healthcare, research, nuclear energy, industrial applications, and other workplaces.

Because occupational exposure to ionizing radiation can affect human tissue, organizations may use radiation dosimetry to monitor and document worker exposure and support their radiation safety and ALARA programs.

ALARA stands for “As Low As Reasonably Achievable.” It is a fundamental radiation safety principle focused on minimizing occupational radiation exposure while accounting for practical, technical, and economic considerations.

In practice, ALARA programs use measures such as reducing the amount of time spent near radiation sources, increasing distance from the source, using appropriate shielding, monitoring occupational radiation dose, and reviewing exposure trends to identify opportunities to reduce unnecessary exposure.

For organizations regulated by the US Nuclear Regulatory Commission (NRC), ALARA is part of the regulatory framework for radiation protection. Radiation Safety Officers (RSOs) use personnel dosimetry and dose reports to help monitor worker exposure and support their organization’s ALARA program.

ALARA does not mean that any radiation exposure is automatically unsafe. Instead, the goal is to keep occupational exposure as far below applicable dose limits as reasonably achievable.

A Radiation Safety Officer (RSO) is the individual responsible for overseeing an organization’s radiation safety program. Depending on the organization and applicable regulations, an RSO’s responsibilities may include implementing radiation safety procedures, overseeing personnel monitoring, reviewing occupational dose reports, maintaining required records, investigating unusual exposures, providing or coordinating radiation safety training, and supporting regulatory compliance.

RSOs also play an important role in maintaining occupational radiation exposure as low as reasonably achievable (ALARA).

The specific qualifications, responsibilities, and regulatory requirements for an RSO vary depending on the types of radiation sources used and the federal or state regulations that apply to the organization.

Occupational dose is the radiation dose a worker receives as a result of performing their job. It can include external radiation exposure as well as internal exposure from radioactive materials, depending on the work environment.

Personnel dosimeters such as whole body badges, ring dosimeters, and digital dosimeters are commonly used to monitor external occupational radiation exposure. The resulting dose records help Radiation Safety Officers (RSOs) track employee exposure over time, identify trends, support ALARA practices, and maintain required occupational dose records.

Occupational dose does not generally include radiation exposure received as a patient during medical procedures or normal background radiation.

A dosimeter wear period is the length of time a personnel dosimeter is assigned to an individual before the monitoring period ends. Common wear periods for passive dosimeters include monthly, bi-monthly, and quarterly monitoring.

At the end of each wear period, passive dosimeters are typically returned for processing and replaced with dosimeters for the next monitoring period. The appropriate wear frequency depends on factors such as potential radiation exposure, work environment, regulatory requirements, and the organization’s radiation safety program.

Some dosimeters may follow different monitoring schedules. For example, RDC fetal dosimeters are monitored monthly, while digital dosimeters such as NetDose™ do not require routine physical badge exchanges.

Common types of ionizing radiation encountered in occupational settings include alpha particles, beta particles, X-rays, gamma rays, and neutron radiation.

Alpha particles consist of two protons and two neutrons. They have very low penetrating ability and can be stopped by materials such as paper or the outer layer of skin. However, alpha-emitting radioactive materials can present a significant internal exposure hazard if inhaled, ingested, or introduced into the body.

Beta particles are high-energy electrons or positrons emitted during radioactive decay. They have greater penetrating ability than alpha particles but can generally be shielded using materials such as plastic or acrylic.

X-rays are high-energy electromagnetic radiation commonly produced by equipment used in medical imaging, dentistry, veterinary medicine, security screening, research, and industrial applications.

Gamma rays are also high-energy electromagnetic radiation, but unlike X-rays, they originate from processes within the atomic nucleus. Gamma radiation can penetrate deeply into materials and the body and typically requires dense shielding materials such as lead or concrete.

Neutron radiation consists of free neutrons and may be encountered around nuclear reactors, particle accelerators, certain radioactive sources, and other specialized nuclear or research environments. Neutrons can be highly penetrating and require specialized monitoring and shielding.

Learn more about alpha, beta, gamma, and other common types of ionizing radiation.

Occupational ionizing radiation can be encountered anywhere workers use radiation-producing equipment or work with radioactive materials.

Common workplaces and applications include hospitals and medical imaging departments, dental and veterinary practices, nuclear medicine, radiation therapy, nuclear power and Department of Energy facilities, research laboratories, universities, industrial radiography, manufacturing, and other industrial operations.

The type and potential level of radiation exposure vary significantly by workplace, equipment, procedure, and job responsibility. Radiation safety programs use practices such as shielding, time and distance controls, training, and personnel dosimetry to help monitor and minimize occupational exposure.

Ionizing radiation has enough energy to alter atoms and damage cells and DNA. The potential health effects of radiation exposure depend on factors including the amount of radiation dose received, dose rate, type and energy of the radiation, duration of exposure, and the tissues or organs exposed.

High radiation doses can cause tissue damage and other acute health effects, while cumulative exposure can increase long-term health risks. Occupational radiation safety programs are therefore designed to limit unnecessary exposure and keep radiation doses as low as reasonably achievable (ALARA).

Personnel dosimetry helps organizations monitor occupational exposure over time and identify exposures or trends that may warrant further review.

Radiation can be measured in several ways depending on whether the goal is to measure radiation in an environment, radioactive material, or the radiation dose received by a person.

For occupational radiation exposure, dose is commonly reported in rem or millirem (mrem) in the United States and sievert or millisievert (mSv) internationally. One rem equals 1,000 mrem, and one sievert equals 1,000 mSv.

Personnel radiation exposure can be monitored using devices such as thermoluminescent dosimeters (TLDs), optically stimulated luminescence (OSL) dosimeters, ring dosimeters, neutron dosimeters, and electronic or digital dosimeters.

RDC provides personnel dosimetry solutions that measure and document occupational radiation exposure so Radiation Safety Officers can monitor worker dose and maintain radiation exposure records.

Background radiation is ionizing radiation that is naturally present in the environment. Sources include cosmic radiation from space and naturally occurring radioactive materials found in soil, rocks, air, water, and the human body. Radon is one of the most significant sources of natural background radiation.

Background radiation is important in personnel dosimetry because a dosimeter may be exposed to radiation even when it is not being worn by an employee. Passive dosimetry programs therefore commonly use a control badge to help account for background and transit exposure that is unrelated to a worker’s occupational dose.

The amount of natural background radiation varies by factors such as geographic location and elevation.

Get Started Today

Ready to Simplify Your
Dosimetry Badge Program?

Join 41,000+ organizations who trust Radiation Detection Company for accurate, timely, hassle-free radiation monitoring service.